Batch CAD Cart (0)
  • Cart is empty
  • Clearance fit suggested for outer ring when housing is stationary relative to load.
  • Tight transition fit suggested if housing rotates relative to load.
  • Consult your Timken representative for oscillating applications (e.g., low radial-clearance concerns).
  • Unmarked end of outer ring should be assembled against housing shoulder to clear maximum allowed housing fillet (ras max).
  • Meets Military Standard MS 51961.
Unit of Measure

Bearing Dimensions

Shaft Diameter (Fw)

N/A 114.30 mm4.50 in

D - Outer Diameter

N/A 152.400 mm6.0000 in

Dimension C/B

N/A 63.5 mm2.5000 in

Specifications

Static Load Rating Co

N/A 599000 N135000 lbf
Dynamic Load Rating C11 N/A 320000 N71900 lbf
Geometry Factor Cg2 N/A 0.1137

Thermal Speed Ratings - Oil

N/A 3200 rpm

Thermal Speed Ratings - Grease

N/A 2800 rpm

Mounting Data

Chamfer rsmin

N/A 2.540 mm0.1 in

Max. Mounting Dimensions Clearance Fit 1

N/A 114.30 mm4.50 in

Min. Mounting Dimensions Clearance Fit 1

N/A 114.277 mm4.4991 in

Max. Mounting Dimensions Clearance Fit 2

N/A 152.441 mm6.0016 in

Min. Mounting Dimensions Clearance Fit 2

N/A 152.400 mm6.000 in

Max. Mounting Dimensions Tight Transition Fit S

N/A 4.4986 mm114.264 in

Min. Mounting Dimensions Tight Transition Fit S

N/A 114.242 mm4.4977 in

Max. Mounting Dimensions Tight Transition Fit H

N/A 152.344 mm5.9978 in

Min. Mounting Dimensions Tight Transition Fit H

N/A 152.385 mm5.9994 in

Shoulder Diameter Da

N/A 138.11 mm5.438 in

Sub Assembly Part Numbers

Used with Inner Ring Designation

N/A IR-607240
  • 1 Based on 1 x 106 revolutions L10 life, for the ISO life calculation method.
  • 2 Cg factor for bearing without inner ring.
By clicking Submit, you consent to the personal information you provide being used in the manner as described in our Privacy Notice, including access to that information by Timken personnel who may be located outside your home country. In addition, you agree that the CAD drawings are for your personal, one-time use only, and that you will not modify or create any compilation or derivative work using the CAD drawings or distribute or display the CAD drawings on any website or other media.