Batch CAD Cart (0)
  • Cart is empty
Type E tapered roller bearing Mounted Bearings are available in a wide variety of sizes and configurations to meet the requirements of demanding applications. Popular part numbers are in stock for immediate availability. Metric sizes also are available in shaft diameters ranging from 35 mm to 125 mm.

Open and Closed end covers available for purchase.
Unit of Measure
Items
Timken_HU_TRB_P2B_TypeE-A

Type E Pillow Block: 2-Bolt Base Bearing

Timken_HU_TRB_P2B_TypeE-A-solidlube

Type E Pillow Block: 2-Bolt Base Bearing

Timken_HU_TRB_P2B_TypeE-A-solidlube

Type E Pillow Block: 2-Bolt Base Bearing

Timken_HU_TRB_P2B_TypeE-A

Type E Pillow Block: 2-Bolt Base Bearing

Timken_HU_TRB_P2B_TypeE-A-solidlube

Type E Pillow Block: 2-Bolt Base Bearing
Shaft Size N/A 1 3/16 in N/A 1 3/16 in N/A 1 3/16 in N/A 1 1/4 in N/A 1 1/4 in
Shaft Size Type N/A Imperial
Dimension B  N/A 2-3/4 in
Dimension L  N/A 6 in
Dimension A  N/A 1-7/8 in
Dimension J Min.  N/A 4-3/4 in
Dimension J Max.  N/A 4-13/16 in
Bolt Diameter  N/A 1/2 in
Dimension N  N/A 9/16 in
Dimension N1  N/A 19/32 in
Dimension H1  N/A 7/8 in
Dimension H2  N/A 3 in
Dimension d1  N/A 2-1/4 in
Dimension H  N/A 1-1/2 in
Dimension Ac  N/A
Dimension d2  N/A
e N/A 0.49
X (if Fa/Fr ≤ e) N/A 0.87
Y (if Fa/Fr ≤ e) N/A 1.77
X (if Fa/Fr > e) N/A 0.7
Y (if Fa/Fr > e) N/A 2.14
K Factor N/A 1.23
C90 Dynamic Load Rating1 N/A 3810 lbf
C0 Static Load Rating N/A 15760 lbf
Fa-max Maximum Permissible Thrust Load2 N/A 2000 lbf
Fr-max Maximum Allowable Slip Fit Radial Load3 N/A 3100 lbf
Max. Speed4 N/A 4490 rpm
UPC Code N/A 053893605982 N/A N/A N/A 053893606439 N/A
Type E Open Cover Number N/A
Type E Closed Cover Number N/A
Lubrication N/A Grease - Premium Industrial N/A Solid Lube - Industrial N/A Solid Lube - Food Grade N/A Grease - Premium Industrial N/A Solid Lube - Industrial
Housing Coating N/A E-Coat
Weight N/A 4 lb
  • 1 C90 is the Dynamic Load Rating based on a rated Life of 90 million revolutions (3000 hrs at 500 RPM).
  • 2 Fa-max is based on the limits of the holding force of two properly tightened collars and set screws. Fifty percent of the values should be used when a single collar is installed.
  • 3 If the application loads approach or exceed Fr-max, the shaft fit should be adjusted to a line-to-line (g6 or h6) or light press fit (m6).
  • 4 Timken Double Lip Seal