Batch CAD Cart (0)
  • Cart is empty
Type E tapered roller bearing Mounted Bearings are available in a wide variety of sizes and configurations to meet the requirements of demanding applications. Popular part numbers are in stock for immediate availability. Metric sizes also are available in shaft diameters ranging from 35 mm to 125 mm.
Unit of Measure
Items
Timken_HU_TRB_P4B_TypeE-A

Type E Pillow Block: 4-Bolt Base Bearing

Type E Pillow Block 4-Bolt Base Bearing - ECC

Type E Pillow Block: 4-Bolt Base Bearing

Type E Pillow Block 4-Bolt Base Bearing - ECO-ECC

Type E Pillow Block: 4-Bolt Base Bearing

Type E Pillow Block 4-Bolt Base Bearing - ECO-ECC

Type E Pillow Block: 4-Bolt Base Bearing

Type E Pillow Block 4-Bolt Base Bearing - ECO

Type E Pillow Block: 4-Bolt Base Bearing
Shaft Size N/A 2 1/4 in
Shaft Size Type N/A Imperial
Dimension B  N/A 4 in
Dimension L  N/A 10-1/2 in
Dimension A  N/A 3-1/2 in
Dimension J Min.  N/A 8-5/16 in
Dimension J Max.  N/A 8-11/16 in
Bolt Diameter  N/A 5/8 in
Dimension N  N/A 11/16 in
Dimension N1  N/A 7/8 in
Dimension N2  N/A 1-7/8 in
Dimension H1  N/A 1-5/8 in
Dimension H2  N/A 5-23/32 in
Dimension d1  N/A 4-1/16 in
Dimension H  N/A 2-3/4 in
Dimension Ac  N/A N/A 4.575 in N/A 5.75 in N/A 5.85 in N/A 4.675 in
Dimension d2  N/A N/A 4.945 in N/A 4.945 in N/A 4.945 in N/A 4.945 in
e N/A 0.40
X (if Fa/Fr ≤ e) N/A 0.87
Y (if Fa/Fr ≤ e) N/A 2.17
X (if Fa/Fr > e) N/A 0.7
Y (if Fa/Fr > e) N/A 2.63
K Factor N/A 1.51
C90 Dynamic Load Rating1 N/A 11600 lbf
C0 Static Load Rating N/A 54000 lbf
Fa-max Maximum Permissible Thrust Load2 N/A 3454 lbf
Fr-max Maximum Allowable Slip Fit Radial Load3 N/A 9500 lbf
Max. Speed4 N/A 2420 rpm
UPC Code N/A 053893607498 N/A 0883450504256 N/A 0883450505888 N/A 0883450509114 N/A 0883450507486
Type E Open Cover Number N/A N/A N/A EUDR-2 1/4 N/A EUDR-2 1/4 N/A EUDR-2 1/4
Type E Closed Cover Number N/A N/A EUC-F N/A EUC-F N/A N/A
Lubrication N/A Grease - Premium Industrial
Housing Coating N/A E-Coat
Weight N/A 23 lb
  • 1 C90 is the Dynamic Load Rating based on a rated Life of 90 million revolutions (3000 hrs at 500 RPM).
  • 2 Fa-max is based on the limits of the holding force of two properly tightened collars and set screws. Fifty percent of the values should be used when a single collar is installed.
  • 3 If the application loads approach or exceed Fr-max, the shaft fit should be adjusted to a line-to-line (g6 or h6) or light press fit (m6).
  • 4 Timken Double Lip Seal