Aerospace / Military Commercial / Industrial Technical Resources Online Catalog
Engineers power search our entire catalog of bearing and bushings, with access to every attribute and technical specification possible. View our online catalog...
CAD (0)
  • Cart is empty
  • Each assembly includes the housing cap and base, cap bolts, bearing, bearing adapter, locknut and lockwasher, stabilizing ring and triple ring seals.
  • To order pillow block housing only, use the numbers listed in the "Housing Only" column. These units include: cap, base, cap bolts, triple ring seals and stabilizing ring.
  • Assembly and pillow blocks described on this page constitute fixed units.
  • To order float units, specify part number plus suffix "Float" or "FL".
  • If one end closed assembly is required, specify “CL” in assembly number when ordering.
  • All assemblies shown are furnished in cast iron. If cast steel is desired, add the letter “S” to the alpha prefix (e.g., SDAFS 23152K).

When ordering non-standard pillow block assemblies specify the shaft size.
Unit of Measure

Specifications

Bearing Number

N/A 23196K

Diameter S-1

N/A 18.0000 in

A

N/A 18 in

B

N/A 54.25 in

C

N/A 21.625 in

D

N/A 5.75 in

E Max.

N/A 48.875 in

E Min.

N/A 47.125 in

F

N/A 15 in

H

N/A 35.75 in

L

N/A 22.25 in

Bolt Hole Length

N/A 3.375 in

Bolt Hole Width

N/A 2.5 in
Adapter Assembly Number1 N/A SNP-3196 x 18
Housing Only2 N/A SDAF3196K x 18
Stabilizing Ring 1 Req'd3 N/A A8998

Triple Seal Req'd

N/A ER 888-1

Full Timken Part Number

N/A SDAF23196K18

Basic Load Ratings

C0 - Static Radial Rating

N/A 2790000 lbf12400000 N

C1(2) - Dynamic Radial Rating (Two-Rows)

N/A 1600000 lbf7110000 N

Factors

e - ISO Factor4 N/A 0.3
Y0 - ISO Factor5 N/A 2.21
Y1 - ISO Factor6 N/A 2.26
Y2 - ISO Factor7 N/A 3.36

Reference Thermal Speed Rating (Grease)

N/A 360 rpm
Reference Thermal Speed Rating (Oil)8 N/A 390 rpm
Cg - Geometry Factor9 N/A 0.1042
  • 1 Includes sleeve, locknut and lockwasher. Add shaft size to order.
  • 2 "Housing Only" includes: cap, base, cap bolts, triple ring seals and stabilizing ring as required. When ordering non-standard housing only specify the shaft size.
  • 3 Stabilizing ring is used for fixed (FX) block; do not use for float (FL) mounting.
  • 4 These factors apply for both inch and metric calculations. Consult your Timken representative for instruction on use.
  • 5 These factors apply for both inch and metric calculations. See engineering
  • 6 These factors apply for both inch and metric calculations. Consult your Timken representative for instruction on use.
  • 7 These factors apply for both inch and metric calculations. Consult your Timken representative for instruction on use.
  • 8 See thermal speed ratings in the engineering section.
  • 9 Geometry constant for Lubrication Life Adjustment Factor a3l.