Batch CAD Cart (0)
  • Cart is empty

RunRight® tensioner devices offer a full range of belt and chain tensioning options. They are manufactured with the standard Tensys™ 10 rubber inserts and can be used for applications operating within a -40° to 180°F (-40° to 80°C) temperature range.

RunRight RT N tensioners are manufactured with galvanized powder metal parts and are designed for outdoor or oily applications. The Tensys 20 neoprene inserts are oil resistant and can be used for applications operating within a -22° to 195°F (-30° to 90°C) temperature range.

RunRight RT H tensioners enable a reduction of tensioning force of up to 40% when compared to the RT and RT N tensioners. The Tensys 40 heat resistant rubber inserts are ideal for applications operating within a 180° to 250°F (80° to 120°C) temperature range.

RunRight RT R tensioners are for use on internal combustion engines and compressors. They are manufactured with powder metal or cast iron housings, fully welded steel arms and inner square, come with the standard Tensys 10 rubber inserts and can be used for applications operating within a -40° to 180°F (-40° to 80°C) temperature range.

The housings are manufactured from powder metal, anything larger is manufactured out of cast iron. All arms and inner squares are cast iron. All of the tensioners include a zinc plated mounting screw and locking washer.

Unit of Measure

Specifications

Description 

N/A RT-N-15-TENSNR MM GALV

Type

N/A Chain/Belt Tensioner

Element Material

N/A Neoprene

Style

N/A Elastomeric

Color

N/A Metallic

Dimensional Data

Tensioner

N/A RT N15-M

Mounting Bolt Size

N/A M8 x 25

Outside Diameter (Dim D)

N/A 45 mm1.77 in

Overall Length (Dim E)

N/A 64 mm2.52 in

Dimension T

N/A 10.5 mm

Dimension L

N/A 112.5 mm4.43 in

Dimension J-1

N/A 100 mm3.94 in

Dimension J-2

N/A 80 mm3.15 in

Dimension M

N/A 25 mm

Dimension G

N/A 5 mm0.2 in

Dimension O

N/A 8 mm0.31 in

Dimension P

N/A 8.5 mm0.33 in

Dimension K

N/A 25 mm0.98 in

Performance Data

Normal Temperature Range

N/A -22 to 195 ºC-30 to 90 ºF

Mounting Bolt Torque

N/A 25 N·m221 in·lb

Force at 20° Angle of Pretension (Normal Force Level) (Dimension F)

N/A 65 N14.6 lb

Distance at 20° Angle of Pretension (Normal Force Level) (Dimension S)

N/A 34 mm1.3 in

Notes

Notes 

N/A
  • The recommended angle of pretension is 20°. This provides the tensioner a maximum capability to absorb vibrations and shock loads, while also maintaining a range of motion to address the system’s belt or chain stretch.
  • Mounting accessories into the “Hard” Position results in approximately 25% higher tensioning force over the “normal” position.
  • Metric standard tensioner units all come with a mounting screw, but do not come with the sprocket idler bolt (which is supplied instead with RunRight metric idler sprockets).
By clicking Submit, you consent to the personal information you provide being used in the manner as described in our Privacy Notice, including access to that information by Timken personnel who may be located outside your home country. In addition, you agree that the CAD drawings are for your personal, one-time use only, and that you will not modify or create any compilation or derivative work using the CAD drawings or distribute or display the CAD drawings on any website or other media.