Batch CAD Cart (0)
  • Cart is empty
  • Clearance fit suggested for outer ring when housing is stationary relative to load.
  • Tight transition fit suggested if housing rotates relative to load.
  • Consult your Timken representative for oscillating applications (e.g., low radial-clearance concerns).
  • Unmarked end of outer ring should be assembled against housing shoulder to clear maximum allowed housing fillet (ras max).
  • Meets Military Standard MS 51961.
Unit of Measure

Bearing Dimensions

Shaft Diameter (Fw)

N/A 107.95 mm4.25 in

D - Outer Diameter

N/A 133.350 mm5 1/4 in

Dimension C/B

N/A 50.8 mm2.0000 in

Specifications

Static Load Rating Co

N/A 444000 N99900 lbf
Dynamic Load Rating C11 N/A 203000 N45700 lbf
Geometry Factor Cg2 N/A 0.1099

Thermal Speed Ratings - Oil

N/A 3300 rpm

Thermal Speed Ratings - Grease

N/A 2900 rpm

Mounting Data

Chamfer rsmin

N/A 2.540 mm0.1 in

Max. Mounting Dimensions Clearance Fit 1

N/A 107.95 mm4.25 in

Min. Mounting Dimensions Clearance Fit 1

N/A 107.927 mm4.2491 in

Max. Mounting Dimensions Clearance Fit 2

N/A 133.391 mm5.2516 in

Min. Mounting Dimensions Clearance Fit 2

N/A 133.350 mm5.250 in

Max. Mounting Dimensions Tight Transition Fit S

N/A 4.2486 mm107.914 in

Min. Mounting Dimensions Tight Transition Fit S

N/A 107.892 mm4.2477 in

Max. Mounting Dimensions Tight Transition Fit H

N/A 133.294 mm5.2478 in

Min. Mounting Dimensions Tight Transition Fit H

N/A 133.335 mm5.2494 in

Shoulder Diameter Da

N/A 123.83 mm4.875 in

Sub Assembly Part Numbers

Used with Inner Ring Designation

N/A IR-566832 IR-606832
  • 1 Based on 1 x 106 revolutions L10 life, for the ISO life calculation method.
  • 2 Cg factor for bearing without inner ring.
By clicking Submit, you consent to the personal information you provide being used in the manner as described in our Privacy Notice, including access to that information by Timken personnel who may be located outside your home country. In addition, you agree that the CAD drawings are for your personal, one-time use only, and that you will not modify or create any compilation or derivative work using the CAD drawings or distribute or display the CAD drawings on any website or other media.