Batch CAD Cart (0)
  • Cart is empty
  • Clearance fit suggested for outer ring when housing is stationary relative to load.
  • Tight transition fit suggested if housing rotates relative to load.
  • Consult your Timken representative for oscillating applications (e.g., low radial-clearance concerns).
  • Unmarked end of outer ring should be assembled against housing shoulder to clear maximum allowed housing fillet (ras max).
  • Meets Military Standard MS 51961.
Unit of Measure

Bearing Dimensions

Shaft Diameter (Fw)

N/A 95.25 mm3.75 in

D - Outer Diameter

N/A 120.650 mm4 3/4 in

Dimension C/B

N/A 50.8 mm2.0000 in

Specifications

Static Load Rating Co

N/A 398000 N89400 lbf
Dynamic Load Rating C11 N/A 193000 N43300 lbf
Geometry Factor Cg2 N/A 0.1011

Thermal Speed Ratings - Oil

N/A 3700 rpm

Thermal Speed Ratings - Grease

N/A 3300 rpm

Mounting Data

Chamfer rsmin

N/A 2.540 mm0.1 in

Max. Mounting Dimensions Clearance Fit 1

N/A 95.25 mm3.75 in

Min. Mounting Dimensions Clearance Fit 1

N/A 95.227 mm3.7491 in

Max. Mounting Dimensions Clearance Fit 2

N/A 120.691 mm4.7516 in

Min. Mounting Dimensions Clearance Fit 2

N/A 120.650 mm4.750 in

Max. Mounting Dimensions Tight Transition Fit S

N/A 3.7487 mm95.217 in

Min. Mounting Dimensions Tight Transition Fit S

N/A 95.192 mm3.7477 in

Max. Mounting Dimensions Tight Transition Fit H

N/A 120.594 mm4.7478 in

Min. Mounting Dimensions Tight Transition Fit H

N/A 120.635 mm4.7494 in

Shoulder Diameter Da

N/A 111.13 mm4.375 in

Sub Assembly Part Numbers

Used with Inner Ring Designation

N/A IR-506032 IR-526032
  • 1 Based on 1 x 106 revolutions L10 life, for the ISO life calculation method.
  • 2 Cg factor for bearing without inner ring.
By clicking Submit, you consent to the personal information you provide being used in the manner as described in our Privacy Notice, including access to that information by Timken personnel who may be located outside your home country. In addition, you agree that the CAD drawings are for your personal, one-time use only, and that you will not modify or create any compilation or derivative work using the CAD drawings or distribute or display the CAD drawings on any website or other media.