Batch CAD Cart (0)
  • Cart is empty
  • Clearance fit suggested for outer ring when housing is stationary relative to load.
  • Tight transition fit suggested if housing rotates relative to load.
  • Consult your Timken representative for oscillating applications (e.g., low radial-clearance concerns).
  • Unmarked end of outer ring should be assembled against housing shoulder to clear maximum allowed housing fillet (ras max).
  • Meets Military Standard MS 51961.
Unit of Measure

Bearing Dimensions

Shaft Diameter (Fw)

N/A 234.95 mm9.25 in

D - Outer Diameter

N/A 282.575 mm11.1250 in

Dimension C/B

N/A 76.2 mm3.0000 in

Specifications

Static Load Rating Co

N/A 1350000 N326000 lbf
Dynamic Load Rating C11 N/A 599000 N145000 lbf
Geometry Factor Cg2 N/A 0.1885

Thermal Speed Ratings - Oil

N/A 1300 rpm

Thermal Speed Ratings - Grease

N/A 1200 rpm

Mounting Data

Chamfer rsmin

N/A 4.060 mm0.16 in

Max. Mounting Dimensions Clearance Fit 1

N/A 234.95 mm9.25 in

Min. Mounting Dimensions Clearance Fit 1

N/A 234.920 mm9.2488 in

Max. Mounting Dimensions Clearance Fit 2

N/A 282.626 mm11.1270 in

Min. Mounting Dimensions Clearance Fit 2

N/A 282.575 mm11.125 in

Max. Mounting Dimensions Tight Transition Fit S

N/A 9.2480 mm234.899 in

Min. Mounting Dimensions Tight Transition Fit S

N/A 234.869 mm9.2468 in

Max. Mounting Dimensions Tight Transition Fit H

N/A 282.509 mm11.1220 in

Min. Mounting Dimensions Tight Transition Fit H

N/A 282.560 mm11.1240 in

Shoulder Diameter Da

N/A 266.70 mm10.500 in

Sub Assembly Part Numbers

Used with Inner Ring Designation

N/A IR-12814848
  • 1 Based on 1 x 106 revolutions L10 life, for the ISO life calculation method.
  • 2 Cg factor for bearing without inner ring.
By clicking Submit, you consent to the personal information you provide being used in the manner as described in our Privacy Notice, including access to that information by Timken personnel who may be located outside your home country. In addition, you agree that the CAD drawings are for your personal, one-time use only, and that you will not modify or create any compilation or derivative work using the CAD drawings or distribute or display the CAD drawings on any website or other media.