Batch CAD Cart (0)
  • Cart is empty
  • Clearance fit suggested for outer ring when housing is stationary relative to load.
  • Tight transition fit suggested if housing rotates relative to load.
  • Consult your Timken representative for oscillating applications (e.g., low radial-clearance concerns).
  • Unmarked end of outer ring should be assembled against housing shoulder to clear maximum allowed housing fillet (ras max).
  • Meets Military Standard MS 51961.
Unit of Measure

Bearing Dimensions

Shaft Diameter (Fw)

N/A 152.40 mm6.00 in

D - Outer Diameter

N/A 190.5 mm7.5 in

Dimension C/B

N/A 76.2 mm3.0000 in

Specifications

Static Load Rating Co

N/A 984000 N221000 lbf
Dynamic Load Rating C11 N/A 438000 N98400 lbf
Geometry Factor Cg2 N/A 0.1461

Thermal Speed Ratings - Oil

N/A 2200 rpm

Thermal Speed Ratings - Grease

N/A 2000 rpm

Mounting Data

Chamfer rsmin

N/A 3.050 mm0.12 in

Max. Mounting Dimensions Clearance Fit 1

N/A 152.40 mm6.00 in

Min. Mounting Dimensions Clearance Fit 1

N/A 152.375 mm5.9990 in

Max. Mounting Dimensions Clearance Fit 2

N/A 190.546 mm7.5018 in

Min. Mounting Dimensions Clearance Fit 2

N/A 190.500 mm7.500 in

Max. Mounting Dimensions Tight Transition Fit S

N/A 5.9984 mm152.359 in

Min. Mounting Dimensions Tight Transition Fit S

N/A 152.334 mm5.9974 in

Max. Mounting Dimensions Tight Transition Fit H

N/A 190.439 mm7.4976 in

Min. Mounting Dimensions Tight Transition Fit H

N/A 190.485 mm7.4994 in

Shoulder Diameter Da

N/A 176.21 mm6.938 in

Sub Assembly Part Numbers

Used with Inner Ring Designation

N/A IR-809648
  • 1 Based on 1 x 106 revolutions L10 life, for the ISO life calculation method.
  • 2 Cg factor for bearing without inner ring.
By clicking Submit, you consent to the personal information you provide being used in the manner as described in our Privacy Notice, including access to that information by Timken personnel who may be located outside your home country. In addition, you agree that the CAD drawings are for your personal, one-time use only, and that you will not modify or create any compilation or derivative work using the CAD drawings or distribute or display the CAD drawings on any website or other media.