●   UCFL two-bolt flanged units are suggested for industrial applications where normal loads are encountered.
●   This series is primarily designed for applications where the mounting area is restricted.
●   Each unit comes assembled and ready for mounting, using bolts through the flange.
●   These units use wide inner ring ball bearings with self-aligning spherical outside diameters that compensate for shaft misalignment.
●   Timken UCFL series Mounted Bearings feature the Timken set screw locking (UC) bearing insert.
●   Bearing prelubricated and ready for immediate installation.
●   Grease fitting supplied for relubrication.
●   The bonded seal design is well-suited for applications involving wet or dirty environments.
●   Bolt-hole spacing dimensions and shaft center location are interchangeable with competitive units.
Unit of Measure

Specifications

Bore Size

1 9/16 in

Seal Type

IP69K Seal

Housing Material

Blue Thermoset (Polymer)

Bearing Number

SUC208-25-IP69K/F

Lubrication Type

Standard Food Safe Grease

Locking Style

Set Screw Locking

Housing Construction

Two-Bolt Flange

Dimensions

Total Length H

6.781 in172.2 mm

Total Height L

4.560 in115.8 mm

Total Width A0

1.957 in49.7 mm

Bolt Hole Spacing J

5.656 in143.8 mm

Housing Width A

1.240 in31.5 mm

Bolt Hole Size N

0.531 in13.5 mm

Center of Bearing from Housing End A2

0.768 in19.5 mm

Center of Bearing from Bearing End S

0.748 in19.0 mm

Inner Ring Width B

1.937 in49.2 mm

Basic Load Ratings

Dynamic Load Rating

5576 lbf24800 N

Static Load Rating

3215 lbf14300 N