TDI bearings have a one-piece double inner race and two single outer races and are typically supplied complete with an outer race spacer as a pre-set assembly. The bearing can be used at fixed positions on rotation shaft applications. For rotating housing application it can be used to float on the stationary shaft.

RELATED PRODUCTS

RELATED PRODUCTS

RELATED PRODUCTS

Unit of Measure

Key Dimensions

Cone Part Number

N/A EE161362D

Bore (d)

N/A 13.6250 in346.075 mm
Dynamic Radial Load Rating - 1M Revs (C1) 1 N/A 123000 lbf548000 N
Dynamic Radial Load Rating - 90M Revs (C90) 2 N/A 31900 lbf142000 N
Dynamic Radial Load Rating 2-Row - 90M Revs (C90-2row) 3 N/A 55600 lbf247000 N
K Factor 4 N/A 1.17

Other Dimensions

Weight

N/A 51.500 Kg113.5 lb

Inner Ring Width (B)

N/A 3.7500 in95.250 mm
Max Shaft Fillet Radius5 N/A 0.06 in1.5 mm

Shaft Backing Shoulder Dia. - Frontface (da)

N/A 14.49 in368 mm

Cage Location rel. to FF (Ab)

N/A 0.22 in5.6 mm

Ratings

Dynamic Axial Rating - 90M Revs (Ca90)6 N/A 27400 lbf122000 N
Dynamic Radial Load Rating 2-Row - 1M Revs (C1)7 N/A 214000 lbf954000 N

Static Radial Load Rating (C0)

N/A 250000 lbf1110000 N

Factors

Geometry Factor (Cg)8 N/A 0.174
  • 1 Based on 1 x 106 revolutions L10 life, for the ISO life calculation method.
  • 2 Based on 90 x 106 revolutions L10 life, for The Timken Company life calculation method. C90 and Ca90 are radial and thrust values.
  • 3 Based on 90 x 106 revolutions L10 life, for The Timken Company life calculation method. C90 and Ca90 are radial and thrust values for a single-row, C90(2) is the two-row radial value.
  • 4 These factors apply for both inch and metric calculations. Consult your Timken representative for instruction on use.
  • 5 These maximum fillet radii will be cleared by the bearing corners.
  • 6 Based on 90 x 106 revolutions L10 life, for The Timken Company life calculation method. C90 and Ca90 are radial and thrust values for a single-row, C90(2) is the two-row radial value.
  • 7 Based on 1 x 106 revolutions L10 life, for the ISO life calculation method.
  • 8 Geometry constant for Lubrication Life Adjustment Factor a3l.