TDI bearings have a one-piece double inner race and two single outer races and are typically supplied complete with an outer race spacer as a pre-set assembly. The bearing can be used at fixed positions on rotation shaft applications. For rotating housing application it can be used to float on the stationary shaft.

RELATED PRODUCTS

Unit of Measure

Key Dimensions

Cone Part Number

N/A HH224346DD

Bore (d)

N/A 4.5000 in114.300 mm
Dynamic Radial Load Rating - 1M Revs (C1) 1 N/A 153000 lbf680000 N
Dynamic Radial Load Rating - 90M Revs (C90) 2 N/A 39600 lbf176000 N
Dynamic Radial Load Rating 2-Row - 90M Revs (C90-2row) 3 N/A 69000 lbf307000 N
K Factor 4 N/A 1.79

Other Dimensions

Weight

N/A 21.5 Kg47.50 lb

Inner Ring Width (B)

N/A 6.0000 in152.400 mm
Max Shaft Fillet Radius5 N/A 0.13 in3.300 mm

Shaft Backing Shoulder Dia. - Frontface (da)

N/A 5.24 in133.16 mm

Cage Location rel. to FF (Ab)

N/A -0.04 in-1 mm

Ratings

Dynamic Axial Rating - 90M Revs (Ca90)6 N/A 22100 lbf98300 N
Dynamic Radial Load Rating 2-Row - 1M Revs (C1)7 N/A 266000 lbf1180000 N

Static Radial Load Rating (C0)

N/A 204000 lbf906000 N

Factors

G1 Factor

N/A 367

G2 Factor

N/A 47.8
Geometry Factor (Cg)8 N/A 0.118
  • 1 Based on 1 x 106 revolutions L10 life, for the ISO life calculation method.
  • 2 Based on 90 x 106 revolutions L10 life, for The Timken Company life calculation method. C90 and Ca90 are radial and thrust values.
  • 3 Based on 90 x 106 revolutions L10 life, for The Timken Company life calculation method. C90 and Ca90 are radial and thrust values for a single-row, C90(2) is the two-row radial value.
  • 4 These factors apply for both inch and metric calculations. Consult your Timken representative for instruction on use.
  • 5 These maximum fillet radii will be cleared by the bearing corners.
  • 6 Based on 90 x 106 revolutions L10 life, for The Timken Company life calculation method. C90 and Ca90 are radial and thrust values for a single-row, C90(2) is the two-row radial value.
  • 7 Based on 1 x 106 revolutions L10 life, for the ISO life calculation method.
  • 8 Geometry constant for Lubrication Life Adjustment Factor a3l.